CONTROL PANELS

SINGLE-PHASE CONTROL PANEL WITH CAPACITOR


SINGLE-PHASE CONTROL PANEL WITH CAPACITOR
CHARACTERISTICS OF THE PRODUCT

The control panels range IC are developed to control one singlephase electropump with thermal protection and starting capacitor.

Input voltage 1 ~ 50/60Hz 230V ±10%
Luminous main switch 0 - 1
Starting capacitor
An input for a float switch or a pressure switch
Thermal protection with external reset button
Thermoplastic box
Outlets with cable-holders
Protection grade IP54
Arrangement for wall mounting
Ambient temperature: -5/+40°C
Relative humidity at 40°C: 50% (not condensed)

TECHNICAL SPECIFICATIONS

 
icona pdf
   DOWNLOAD TECHNICAL SHEET
 
 

ELECTRONIC CONTROL PANEL WITH PROTECTION AGAINST DRY WORKING WITHOUT PROBES


ELECTRONIC CONTROL PANEL WITH PROTECTION AGAINST DRY WORKING WITHOUT PROBES
CHARACTERISTICS OF THE PRODUCT

The control panels range SELF-CONTROL are studied for the starting of a single-phase or three-phase electropump. They are suitable for the protection against dry-working without the use of level probes and equipped with protections.

Input voltage 1 ~ 50 Hz 230 V ± 10% (single-phase only)
Input voltage 3 ~ 50 Hz 400 V ± 10% (three-phase only)
Display LED 7 seg. absorbed current visualization
Internal capacitor (single-phase only)
Auxiliary input float / pressure switch
Automatic setting of the parameters or manual insertion of the data
Protection of the electropump against dry-working by cosφ check and
resetting after 10-20-40-80-120 minutes
Motor overlaod electronic protection
Phase failure protection (three-phase only)
Low voltage (-15%) and overvoltage protection (+15%)
Index protection IP55
Cable glands PG21 e PG11

TECHNICAL SPECIFICATIONS

 
icona pdf
   DOWNLOAD TECHNICAL SHEET
 icona pdf
   DOWNLOAD HANDBOOK
 

SINGLE-PHASE OR THREE-PHASE ELECTROMECHANICAL CONTROL PANEL


SINGLE-PHASE OR THREE-PHASE ELECTROMECHANICAL CONTROL PANEL
CHARACTERISTICS OF THE PRODUCT

The electromechanical control panels range BASIC are for direct starting, developed for the control of a  single-phase or three-phase electropump and equipped with protections.

Input voltage 1 ~ 50/60Hz 230V ±10% (BASIC - M)
Input voltage 3 ~ 50/60Hz 400V ±10% (BASIC - T)
Transformer for auxiliary circuits 400+230/24V (BASIC - T only)
Internal capacitor ( BASIC - M only)
Input for a float switch or a pressure switch
Selector Automatic (stable) - 0 - Manual (unstable)
Green led for motor operating
Red led for motor protection alarm
Line contactor AC3 class
Overload thermal relay internally restorable
Auxiliary circuits and motor protection fuses
Enclosure in thermoplastic (ABS)
Outputs with cable-holders
Index Protection IP55
Ambient temperature: -5/+40°C
Relative humidity at 40°C: 50% (not condensed)

TECHNICAL SPECIFICATIONS

 
icona pdf
   DOWNLOAD TECHNICAL SHEET
 
 

ELECTROMECHANICAL PANEL WITH DIRECT STARTING


ELECTROMECHANICAL PANEL WITH DIRECT STARTING
CHARACTERISTICS OF THE PRODUCT

The electromechanical control panels range DIR are developed for the control of one three-phase electropump and equipped with protections.

Input voltage 3 ~ 50/60Hz 400V ± 10%
Transformer for auxiliary circuits 400+230/24V
Selector for Automatic (stable) - 0 - Manual (unstable)
Input for a float switch or a pressure switch
Blue led for power on
Green led for motor operating
Red led for motor protection alarm
Line contactor AC3 class
Overload thermal relay internally restorable
Auxiliary circuits and motor protection fuses
Main switch with door interlock
Metallic cabinet
Index Protection IP55
Ambient temperature: -5/+40°C
Relative humidity at 40°C: 50% (not condensed)

TECHNICAL SPECIFICATIONS

 
icona pdf
   DOWNLOAD TECHNICAL SHEET
 
 

ELECTROMECHANICAL PANEL WITH IMPEDANCE STARTING SYSTEM (STATORIC)


ELECTROMECHANICAL PANEL WITH IMPEDANCE STARTING SYSTEM (STATORIC)
CHARACTERISTICS OF THE PRODUCT

The electromechanical control panels are developed for statoric impedance starting of a three-phase electropump and equipped with protections.

Input voltage 3 ~ 50/60Hz 400V ± 10%
Transformer for auxiliary circuits 400+230/24V
Selector for Automatic (stable) - 0 - Manual (unstable)
Input for a float switch or a pressure switch
Blue led for power on
Green led for motor operating
Red led for motor protection alarm
Line contactor AC3 class
Impedance starter contactor AC3 class
Impedance starter
N°4 starts per hour which not more than 2 consecutively
Acceleration time max. 15 s.
Overload thermal relay internally restorable
Timer for impedance release 0 ÷ 30 s.
Auxiliary circuits and motor protection fuses
Main switch with door interlock
Metallic cabinet
Index Protection IP55
Ambient temperature:-5/+40°C
Relative humidity at 40°C: 50% (not condensed)

TECHNICAL SPECIFICATIONS

 
icona pdf
   DOWNLOAD TECHNICAL SHEET
 
 

ELECTROMECHANICAL PANEL WITH STAR / DELTA STARTING SYSTEM


ELECTROMECHANICAL PANEL WITH STAR / DELTA STARTING SYSTEM
CHARACTERISTICS OF THE PRODUCT

The electromechanical control panels range DELTA are developed for star - delta starting of a three-phase  electropump and equipped with protections.

Input voltage 3 ~ 50/60Hz 400V ± 10%
Transformer for auxiliary circuits 400+230/24V
Selector for Automatic (stable) - 0 - Manual (unstable)
Input for a float switch or a pressure switch
Blue led for power on
Green led for motor operating
Red led for motor protection alarm
Line contactor AC3 class
Contactor for star starting AC3 class
Contactor for delta working AC3 class
Overload thermal relay internally restorable
Timer for star - delta exchange 0 ÷ 30 s.
Auxiliary circuits and motor protection fuses
Main switch with door interlock
Metallic cabinet
Index Protection IP55
Ambient temperature:-5/+40°C
Relative humidity at 40°C: 50% (not condensed)

TECHNICAL SPECIFICATIONS

 
icona pdf
   DOWNLOAD TECHNICAL SHEET
 
 

Agricoltura

Agriculture

Agriculture

Industria

Industrial

Industriel

Civile

Civil

Civil

Approvvigionamento idrico

Water supply system

Approvisionnement hydrique

elettropompe per agricoltura impianti elettrici industriali quadri elettrici civili innevamento artificiale